NFIN RCD (Moeller model RCCB) Application: The Residual Current Device(RCD) NFIN is in conformity with the standards of IEC 1008, VDE 0664, CEE27 and BS 4293. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. NFIN RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerce, hotels and families. It can be used in circuits up to single phase 240V, three phase 415V, 50 or 60Hz. Specificaton: Type NFIN25 Rated current :25A Rated operating current for earth leakage:0.03, 0.1, 0.3, 0.5A Rated non-operating current for earth leakage :0.5/n Voltage Un(V) 240(220) 415(380) Operating time(second):0.2 Limited value of non-operating current for balance load or unbalance load:2/n In minimum value of rated making and breaking capacity: In=25,200 Rated conditional short circuit current Inc(A). 1500 Endurance(times) 4000 Type NFIN40 Rated current :40A Rated operating current for earth leakage:0.03, 0.1, 0.3, 0.5A Rated non-operating current for earth leakage :0.5/n Voltage Un(V) 240(220) 415(380) Operating time(second):0.2 Limited value of non-operating current for balance load or unbalance load:2/n In minimum value of rated making and breaking capacity: In=25,200 Rated conditional short circuit current Inc(A). 1500 Endurance(times) 4000 Type NFIN63 Rated current :63A Rated operating current for earth leakage:0.1, 0.3, 0.5A Rated non-operating current for earth leakage :0.5/n Voltage Un(V) 240(220) 415(380) Operating time(second):0.1 Limited value of non-operating current for balance load or unbalance load:2/n In minimum value of rated making and breaking capacity: In=40,300 Rated conditional short circuit current Inc(A). 2000 Endurance(times) 4000 Type NFIN100 Rated current :100A Rated operating current for earth leakage:0.1, 0.3, 0.5A Rated non-operating current for earth leakage :0.5/n Voltage Un(V) 240(220) 415(380) Operating time(second):0.04 Limited value of non-operating current for balance load or unbalance load:2/n In minimum value of rated making and breaking capacity: In=63,400 Rated conditional short circuit current Inc(A). 3000 Endurance(times) 4000 Aeg mcb MCB AEG AEG MCB UNELEC C45 mcb aeg BKN DX MCB AEG AEG MCB UNELEC C45 NC-100H BKN BKM DX BH BH-P BH-N MG GE AEG PLS6 L7 C65 DZ47 DPN ,C60N, MY MY MW W40 BH-D6 K101 DPX MB H6 S250 E4CB 5SX 5SU MEM SX1-G3 SX2-G3 TQL TQC BHC FN NF CM1 DZ15 DZ10 DZ47LE DPNLE F360 ID NFIN +86-13757778950 LC1-D,3TB,3TF RCCB,RCBO,RCD, Meter, KWH Meter, DD28, DD862 3UA NF-CW,3VL,DPX,NS-100N,NE-100,S ,SERIES,TSERIES,Y,HFD,HHB,ABS,SA,EA,AM8 Miniature Circuit Breaker, Dz47, C45, Mcb, Mccb, Miniature Circuit Breaker, Dz47le, C65, C45N, C16, C10, C25 specializing in producing MEM, Merlin Gerin, LG, F&G, Legrand models Circuit Breakers, and GMC, LC1-D and Airconditioner AC Contactors, and LE1-D, ADS7 Magnetic Starters and Metal Distribution Boxes.
|